The 2000 Controller offers added security in applications where analytical conditions are critical, e.g. wet ashing prior to trace metal analysis or cases where the samples are sensitive to overheating at the start of digestion. The 2000 Controller is included with the 20 and the 40-place digesters.

The Controller can be programmed for a sequence of up to nine combinations of temperature (from ambient to 440°C) and time (up to 100 hours). Several applications can be included in the same program provided that the total number of steps does not exceed nine. This is useful if the equipment is used to process different materials from time to time.

The compact Controller can be either wall or bench mounted. It draws power from the Digestor, so it does not need an independent supply. Extension cable kits can be supplied for remote connection to the Digestor, Lift and Scrubber.

Any loss of power interrupts the cycle; the Digestor stops heating and the Lift goes to the cooling position. If a Scrubber or Flow Regulator is connected, it will stop too.  Thus if a power failure occurs during a critical overnight digestion, there will be no dry tubes in the morning and no wastage of water. The power failure is also indicated on the Controller display to tell the operator that the digestion has not been completed.

The Flow Regulator makes it easy to adjust the flow through a connected water aspirator. An Exhaust works best if the suction is initially set to maximum and then reduced to avoid acid losses. The water flow can be set manually to HIGH, LOW or STOP with the switch. If a Controller is connected, the flow is regulated automatically.

The Controller is programmable in 9 steps. Temperature 30-440
°C. Time from 1 minute up to 99 hours and 59 minutes. Can control all the Digestors, the Lift, the Scrubber and the Flow Regulator.

Specification

Number

Description

Price

2000001 Controller programmable in nine temperature (ambient - 440 ° C) and time steps, to be used in combination with any of the Digestors. Powered from the Digestor. 4,973.91
10005563 Extension Cable, Controller to Lift / Scrubber /Flow Regulator, l = 2 m. 84.43
10005564 Extension Cable, Controller to Digestor, l = 2 m. 84.50
 
Fully unattended operation